Handling Intrusion Detection/Prevention Software

A personal firewall, or intrusion detection/prevention software (IPS or IDPS), can cause Unwired Platform components to malfunction or not function at all. Unwired Platform uses regular IP communication between components on the primary network interface of a computer, even when all components are installed on the same host.

If the local network interface is secured by intrusion detection/prevention software (IPS or IDPS, for example, McAfee Host Intrusion Prevention software or equivalent), you must configurethe security software to allow all network communication between Unwired Platform components.

For a single-node installation of all of the Sybase Unwired Platform components, try one of these options to work around the limitations imposed by the host intrusion prevention software and policy settings, without violating any security policy, until the settings of your security software are adjusted to the needs of Unwired Platform.

Choose an option:
  • Removing the host machine from the network – this option ensures that all interconnections between Sybase Unwired Platform components are treated as local traffic and is not be flagged as incoming connections from external sources, thereby causing connection failures due to security policy setting. This option is suitable when you use your laptop in a network other than your corporate network, and want to demonstrate a mobile solution using a simulator or emulator with all components running on the same machine. To use this option:
    1. Stop the Sybase Unwired Platform services in the correct order. See Starting and Stopping Unwired Platform Server Services in System Administration.
    2. Disconnect the host from all networks.
    3. Restart Sybase Unwired Platform services in the correct order.
    4. Change the Sybase Control Center URL link to use "localhost" or <yourhostname> as the host name, instead of the original fully qualified host name of the machine that included the domain name (for example: https://localhost:8283/scc, or https://yourhostname:8283/scc). Accept any security warnings to connect to Sybase Control Center.
  • Connecting the host to the corporate network – this option ensures that all interconnections among Sybase Unwired Platform components are internal to your corporate network and validated against the corporate network security policy. The option of connecting to corporate network through VPN is especially suitable when you use your laptop in a network other than your corporate network, and want to demonstrate a mobile solution using your physical devices, and need outgoing connections to a backend Enterprise Information System (EIS) or Relay Server (Sybase Hosted Relay Server or otherwise).
    1. Stop the Sybase Unwired Platform services in the correct order. See the Starting and Stopping Unwired Platform Server Services topic in the System Administration.
    2. Reconnect the host to your corporate network directly or through corporate VPN, to ensure that the corporate network security policy applies.
    3. Restart Sybase Unwired Platform services in the correct order.
    4. Change the Sybase Control Center URL link to use "localhost" or <yourhostname> as the host name, instead of the original fully qualified host name of the machine that included the domain name (for example: https://localhost:8283/scc, or https://yourhostname:8283/scc). Accept any security warnings to connect to Sybase Control Center.
  • Configuring the firewall software to allow connections to the ports the Unwired Platform uses. For a list of ports, see Unwired Platform Ports in System Administration.
Always check for the latest available patches and updates for your Unwired Server version on http://downloads.sybase.com/swd/base.do?client=support.
Related concepts
Troubleshooting Host Name Problems
Listeners or Services Could Not be Started Errors
Related tasks
Cannot Access Device Tab and Web Service Error
Cannot Access sampledb
Related reference
Sybase Unwired Server Service Fails to Restart After Credential Change
System Environment Path is Too Long
Client Application Hangs Waiting for Authentication
Performance Issues if Unwired Server Not Installed on a 64-bit Machine
Unwired Server or RSOE Startup Problems