Cannot Access Device Tab and Web Service Error

Problem: After installation, you cannot access the Applications > Application Connections tab in Sybase Control Center, and the Unwired Server log shows an ADMIN_WEBSERVICE_INVOCATION_ERROR.

Explanation: This may indicate you have a port number conflict for the messaging administration Web services server listener port.

Solution: Change the port number.

  1. Navigate to: <UnwiredPlatform_InstallDir>\UnwiredPlatform\Servers\MessagingServer\Bin
  2. At the command line, enter:
    AdminWebServicesTool.exe set=<port>

    Where <port> is the new port number. Alternatively, enter this to change the port number and restart the listener using the new number.

    AdminWebServicesTool.exe set=<port> restart
Related concepts
Troubleshooting Host Name Problems
Listeners or Services Could Not be Started Errors
Related tasks
Handling Intrusion Detection/Prevention Software
Cannot Access sampledb
Related reference
Sybase Unwired Server Service Fails to Restart After Credential Change
System Environment Path is Too Long
Client Application Hangs Waiting for Authentication
Performance Issues if Unwired Server Not Installed on a 64-bit Machine
Unwired Server or RSOE Startup Problems
.NET Environment Problems Affect Unwired Server