Select Tasks from menu bar.
Select Resources.
Select Define a Resource
Field |
Sample value |
Description |
---|---|---|
Resource Type |
SYBASE_DB |
The type of resource to define. The FailSafe system includes predefined resource types, or you can define your own. See your SGI documentation for information. |
Resource |
pri_ase |
Name of the resource to define. |
Click Next. Complete the following fields with the appropriate values.
Field |
Sample value |
Description |
---|---|---|
HA_PWD |
psswrd |
To enter a NULL password, use single quotes |
SYBASE1 |
/usr/sybase |
The local Adaptive Server’s $SYBASE value |
SYBASE2 |
/usr/sybase |
The remote Adaptive Server’s $SYBASE value |
SYBUSER |
sybase |
The IRIX user name who owns $SYBASE. The value is used by IRIX FailSafe to log in and start Adaptive Server. |
MONITOR_INTERVAL |
5 |
How often you ping Adaptive Server using isql. Each ping creates a new isql session, then terminates it. |
SYBASE_ASE |
ASE-12_5 |
The subdirectory within $SYBASE where the Adaptive Server exists. |
SYBASE_OCS |
OCS-12_5 |
The subdirectory within $SYBASE where the Open Client Server binaries exist; specifically, isql. |
HOST1 |
MONEY1 |
The local hostname(1) value. |
HOST2 |
PERSONNEL1 |
The remote hostname(1) value. |
RECOVERY_TIMEOUT |
90 |
The number of seconds that you are willing to wait for Adaptive Server to run through recovery on all its databases. This can take some time, depending on the size of the transaction logs and how many databases are being rolled forward. If you exceed the limit specified, IRIX FailSafe issues an error. |
SHUTDOWN_TIMEOUT |
30 |
The number of seconds you are willing to wait before timing out. |
HA_LOGIN |
sa |
A user with ha_role assigned who has the ability to monitor Adaptive Server and shut it down. |
SYBSERVER1 |
MONEY1 |
The local Adaptive Server’s DSQUERY value. |
SYBSERVER2 |
PERSONNEL1 |
The remote Adaptive Server’s DSQUERY value. |
Click OK.
Select Tasks from menu bar.
Select Resources.
Select Add/Remove Dependencies for a Resource Definition. Enter values for the following fields:
Field |
Sub field |
Sample value |
Description |
---|---|---|---|
Resource Type |
SYBASE_DB |
Select a value from the pull-down list. |
|
Resource |
pri_ase |
The list of values is displayed for the Resource Type. |
|
List of Dependencies |
N/A |
Information line |
|
Dependency Type |
file system |
Similar to a Resource Type. |
|
Dependency Name |
/vol1 |
Similar to a Resource. The list of values is limited based on the Dependency Type. |
Click Add.
Click OK.
From the command line, enter:
cluster_mgr –f pri_ase_resource_def
Copyright © 2005. Sybase Inc. All rights reserved. |
![]() |