Known Issues for Multiplex Environment

Descriptions of known issues and workarounds for the multiplex environment.

Multiplex issues
CR# Description
611990
  • Emergency shutdown on secondary servers after CREATE TEXT INDEX – A secondary server goes into emergency shutdown, when:
    • It is started with the -sf external_library_full_text flag, which disables loading of external libraries, and

    • The user issues a CREATE TEXT INDEX statement on the coordinator with a text configuration that uses external libraries.

    All other servers replay the DDL successfully.
  • Workaround – Start secondary nodes in the multiplex without the -sf external_library_full_text flag.
557714
  • Emergency shutdown on secondary servers after creating a proxy table – A timing problem may cause an emergency server shutdown when a user accesses a new proxy table on a secondary server.
  • Workaround – Either reconnect or wait for some time and start another transaction, before trying to use a newly-created proxy table.
Related concepts
Known Issues for Installation and Configuration
Known Issues for SySAM Licensing
Known Issues for SAP Sybase IQ Operations
Known Issues for Interactive SQL
Related reference
Restrictions