Table 2-5: Connection Router messages
Message text and explanation
|
CICS System CMD call not authorized
Explanation: SYMC and SYMS use LOAD and INQUIRE calls.
This message occurs if the transactions are not authorized to make
these calls.
Action: Contact Sybase Technical Support.
|
Conn router conflicting priorities
Explanation: Priorities must be unique in the server/path file.
Action: Make priority unique in the server/path file.
|
Conn router entry in use
Explanation: The entry that corresponds to the current record is being
used in a conversation.
Action: Try again later.
|
Conn router table not found
Explanation: The Connection Router Table cannot be loaded.
Action: Make sure the library that has the Connection Router CSECT
is in the CICS DFHRPL list.
|
Conn router table not initialized
Explanation: The Connection Router table was not loaded properly.
Action: Initiate the Connection Router Table by running SYM1 CICS
Transaction.
|
Connection router table loaded
Explanation: The Connection Router Table is ready for processing.
Action: No action is required.
|
Data error - correct and press enter
Explanation: An editing error occurred.
Action: Correct the highlighted field(s).
|
Duplicate connection
Explanation: A connection can only appear once in the table.
Action: Check the connection and reenter it.
|
Duplicate record
Explanation: The record already exists in the file.
Action: Update existing record.
|
Duplicate server path
Explanation: Server/MCC path already exists.
Action: Check the server/MCC name and reenter it.
|
Entry not found in conn router table
Explanation: The entry that corresponds to the current record is not in
the Connection Router Table.
Action: Reload the table.
|
Invalid connection id
Explanation: The connection is not defined to CICS.
Action: Add the connection to CICS.
|
Invalid netname for connection
Explanation: The NETNAME corresponding to the connection is not defined
to CICS.
Action: Verify the connection and NETNAME in CICS.
|
No connection entered
Explanation: CONNECTION is a required field for SYMC.
Action: Enter a value in the CONNECTION field.
|
No connection records in file
Explanation: The connection file is empty or disabled.
Action: Check the status of the file using CEMT and add a record
to the connection file, if necessary.
|
No fields modified
Explanation: No fields were changed.
Action: Enter a change.
|
No MCC entered
Explanation: MCC is a required field for SYMC and SYMS.
Action: Enter the MCC name.
|
No server entered
Explanation: SERVER is a required field for SYMS.
Action: Enter the server name.
|
No server/path records in file
Explanation: The server path file is empty or disabled.
Action: Check the status of the file using CEMT and add a server
path record to the file, if necessary.
|
Not enough memory for conn router table
Explanation: The Connection Router table has not been defined with enough
entries.
Action: Reassemble SYCONTBL with additional entries.
|
Press PF6 to delete
Explanation: This is a prompt to verify the deletion of the current record.
Action: Press PF6 to delete the current record.
|