SMPONP-12865 | The HTTPS port of Sybase Control Center (default port is 8283)
poses a SSLv3/TLS renegotiation vulnerability. The vulnerabilities are
described here:
Workaround: N/A
|
SMPONP-11459 | due to a Sybase Unwired Platform version 2.3 installer problem,
Sybase Control Center does not work after upgrading
from Sybase Unwired Platform version 2.2 SP04 or later (for
example 2.2 SP05) to version 2.3. Workaround: Run the
following SQL script after upgrading to fix the
Sybase Control Center issue: - Save this SQL script to a file on the local file system, for
example:
C:\temp\fix_SCC.sql:
begin
UPDATE SEC_CONFIG SET SCFG_VALUE='true' WHERE SCFG_KEY='RESKEY_SECOPT_AUTO_CREATE_LOGIN';
UPDATE SEC_CONFIG SET SCFG_VALUE='true' WHERE SCFG_KEY='RESKEY_SECOPT_AUTO_GRANT_USER_ROLE';
commit;
end;
begin
declare curs2 cursor for
select rtv.rtv_id from "DBA"."RES_RESOURCE_TYPE_VER_M" rtv, "DBA"."RES_RESOURCE_TYPE_M" rt
where
rtv.rtv_rt_id=rt.rt_id and rtv.RTV_SHORT_VER_STR!='Unknown'
and (rt.rt_class='com.sybase.uep.admin.agent.plugin'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.ClusterMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.ServerMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.DomainMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.PackageMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.PersonalizationMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.SubscriptionMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.UserMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.SecurityMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.ConnectionMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.MessageMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.DeviceUserMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.MonitorMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.MBOMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.OperationMO'
or rt.rt_class='com.sybase.uep.sysadmin.management.mo.ApplicationMO'
);
declare current_rtv_id int;
open curs2;
updateVersionLoop:
loop
fetch next curs2 into current_rtv_id;
IF SQLCODE <> 0 THEN LEAVE updateVersionLoop END IF;
update "DBA"."RES_RESOURCE_TYPE_VER_M"
set "RTV_VER_A"=2,
"RTV_VER_B"=3,
"RTV_VER_C"=0,
"RTV_SHORT_VER_STR"=replace(RTV_SHORT_VER_STR, (select REGEXP_SUBSTR(RTV_SHORT_VER_STR, '^\d.\d.\d')), '2.3.0'),
"RTV_DESC"=replace(RTV_DESC, (select REGEXP_SUBSTR(RTV_DESC, '\d.\d.\d')), '2.3.0')
where "RTV_ID"=current_rtv_id;
end loop updateVersionLoop;
close curs2;
commit;
end;
- From the command line, run the SQL
script:C:\SAP\MobilePlatform\Servers\SQLAnywhere16\BIN32\dbisql.exe
-c "uid=dba;pwd=SAP2010_SCC" -host localhost -port 3638
C:\temp\fix_SCC.sql
Note: The
dbisql.exe location varies depending on
your Sybase Unwired Platform installation. The default
Sybase Control Center database password is
"SAP2010_SCC".
- Restart Sybase Control Center.
|
RTC-221 |
Redeploying a package to Unwired Server after changing a Cache Group policy from
"Scheduled" to "On Demand" may result in Sybase Control Center displaying an invalid cache
interval.
Workaround: Update the cache interval in
Sybase Control Center.
|
RTC-225 | Redundant
properties displayed for application templates and connection settings Several push notification properties in the application
connection settings are no longer applicable. - Blackberry Push Notifications:
- BES Notification Name
- Delivery Threshold (Minutes)
- Apple Push Notitifcations
- Delivery Threshold (Minutes)
Workaround: Ignore
these properties.
|
CR-707565 | Domain log purging can take a significant
amount of time if too much data accumulates.Workaround: Purge the domain log at regular
intervals.
|
CR-705003 | Sybase Control Center
does not ask user to delete packages and connections before deleting the
domain.Workaround: Before
you delete a domain, verify package and connection deletion is not an
issue.
|
CR-704917 | If an administrator takes action from
Sybase Control Center
while the primary server is being shut down, you may see an internal or
unexpected error if the server has not completely shut down.Workaround: Before taking any
action in
Sybase Control Center,
ensure that the primary server shutdown is complete and another server has
taken over as the new primary.
|
CR-704913 | When an iOS device goes offline, it
continues to show as being online for about 8 minutes in
Sybase Control Center.Workaround: None.
|
CR-703367 | Domain log messages in Data Sync and
Operation Replay subsystems are not logged to the 'default' domain.Workaround:
- Create a domain log profile for the 'default'
server connection (JDBC type) to enable logging of Data Sync and
Operation Replay messages.
- If you have a similar configuration, make changes
as appropriate. Contact Technical Support for guidance.
|
CR-703321 | Exporting a domain log after upgrading
generates a Domain log export failed error
message.Workaround: Clear
the cache for the browser you are using to access
Sybase Control Center.
|
CR-696373 | When retrieving a domain log for large
data, you receive an unknown error in
Sybase Control Center.Workaround: Check whether the
Unwired Server
or
Sybase Control Center
agent.log reports an out of memory
error. If so, increase the JVM heap size appropriately for
Unwired Server
from the
Sybase Control Center
Configuration tab.
If this does not resolve the
issue, try decreasing the time range set in the domain log in
Sybase Control Center.
|
CR-695792 | Suspending a large volume (100 or more) of DOE-C package
subscriptions may cause
Unwired Server
to stop responding.
Workaround: Suspend subscriptions in batches of no
more than 50.
|
CR-691963 | MBO package deployment in Update mode after adding a new
load argument without default value succeeds even though deployment should
fail.Workaround: None. To
avoid deploying client-incompatible changes,
Sybase
recommends that you first use Verify mode deployment; if verify succeeds,
proceed to Update mode deployment.
|
CR-690482 | Using Firefox, the
Sybase Control Center
main page shows Invalid Login and the
agent.log shows Received fatal alert:
bad_certificate error.Workaround: The Firefox browser appears to be using
an incorrect server certificate. Clean up any such previously existing certificates: - Select .
- Click the Servers tab, then identify existing certificates
issued to the same host to which you are connecting.
- Click Delete to remove all such certificates.
Alternatively, use Internet Explorer.
|
CR-683775 | In some instances, when using the Windows
Services tool or the Stop
Sybase Control Center
Service
shortcut to stop the
Sybase Control Center3.2
service,
Sybase Control Center
displays Stopping in the Windows Control
Panel yet fails to stop.
Workaround: To stop the
Sybase Control Center service: - Launch Windows Task Manager.
- Locate the
sccservice.exe process, right-click and select
End Process Tree. This
option also kills the
Sybase Control Center
database repository server process dbsrv11.exe.
|
n/a | Domains and Packages tab
Sybase Control Center
for Online Data Proxy does not have a way to add a new domain to an
application from the Application Properties dialog. Domains can only be
associated in the Application Creation wizard.
|
RTC-396 | Modification of JVM properties in SCC does not take effect if server is
restarted using Windows ServicesWorkaround: Restart server
from SCC, use restart-unwired-server.bat, or click the
stop/start Unwired Server services icons.
|