Known Issues for Sybase Control Center

Learn about known issues and apply workarounds for Sybase Control Center.

Issue # Description
SMPONP-12865
The HTTPS port of Sybase Control Center (default port is 8283) poses a SSLv3/TLS renegotiation vulnerability.

Workaround: N/A

SMPONP-11459
due to a Sybase Unwired Platform version 2.3 installer problem, Sybase Control Center does not work after upgrading from Sybase Unwired Platform version 2.2 SP04 or later (for example 2.2 SP05) to version 2.3.
Workaround: Run the following SQL script after upgrading to fix the Sybase Control Center issue:
  1. Save this SQL script to a file on the local file system, for example: C:\temp\fix_SCC.sql:
     begin 
    
    UPDATE SEC_CONFIG SET SCFG_VALUE='true' WHERE SCFG_KEY='RESKEY_SECOPT_AUTO_CREATE_LOGIN';
    UPDATE SEC_CONFIG SET SCFG_VALUE='true' WHERE SCFG_KEY='RESKEY_SECOPT_AUTO_GRANT_USER_ROLE';
    commit;
    end;
    
    begin
    declare curs2 cursor for 
    select rtv.rtv_id from "DBA"."RES_RESOURCE_TYPE_VER_M" rtv, "DBA"."RES_RESOURCE_TYPE_M" rt 
    where 
     rtv.rtv_rt_id=rt.rt_id and rtv.RTV_SHORT_VER_STR!='Unknown' 
      and (rt.rt_class='com.sybase.uep.admin.agent.plugin'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.ClusterMO' 
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.ServerMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.DomainMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.PackageMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.PersonalizationMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.SubscriptionMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.UserMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.SecurityMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.ConnectionMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.MessageMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.DeviceUserMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.MonitorMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.MBOMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.OperationMO'
        or rt.rt_class='com.sybase.uep.sysadmin.management.mo.ApplicationMO'
     );
    declare current_rtv_id int;
    open curs2;
    updateVersionLoop:
    loop
     fetch next curs2 into current_rtv_id;
     IF SQLCODE <> 0 THEN LEAVE updateVersionLoop END IF;
    
     update "DBA"."RES_RESOURCE_TYPE_VER_M"
      set  "RTV_VER_A"=2,
           "RTV_VER_B"=3,
           "RTV_VER_C"=0,
           "RTV_SHORT_VER_STR"=replace(RTV_SHORT_VER_STR, (select REGEXP_SUBSTR(RTV_SHORT_VER_STR, '^\d.\d.\d')), '2.3.0'),
           "RTV_DESC"=replace(RTV_DESC, (select REGEXP_SUBSTR(RTV_DESC, '\d.\d.\d')), '2.3.0')
     where "RTV_ID"=current_rtv_id;
    
     end loop updateVersionLoop;
    close curs2;
    commit;
    end; 
  2. From the command line, run the SQL script:C:\SAP\MobilePlatform\Servers\SQLAnywhere16\BIN32\dbisql.exe -c "uid=dba;pwd=SAP2010_SCC" -host localhost -port 3638 C:\temp\fix_SCC.sql
    Note: The dbisql.exe location varies depending on your Sybase Unwired Platform installation. The default Sybase Control Center database password is "SAP2010_SCC".
  3. Restart Sybase Control Center.
RTC-221

Redeploying a package to Unwired Server after changing a Cache Group policy from "Scheduled" to "On Demand" may result in Sybase Control Center displaying an invalid cache interval.

Workaround: Update the cache interval in Sybase Control Center.

RTC-225
Redundant properties displayed for application templates and connection settings
Several push notification properties in the application connection settings are no longer applicable.
  • Blackberry Push Notifications:
    • BES Notification Name
    • Delivery Threshold (Minutes)
  • Apple Push Notitifcations
    • Delivery Threshold (Minutes)

Workaround: Ignore these properties.

CR-707565
Domain log purging can take a significant amount of time if too much data accumulates.

Workaround: Purge the domain log at regular intervals.

CR-705003
Sybase Control Center does not ask user to delete packages and connections before deleting the domain.

Workaround: Before you delete a domain, verify package and connection deletion is not an issue.

CR-704917
If an administrator takes action from Sybase Control Center while the primary server is being shut down, you may see an internal or unexpected error if the server has not completely shut down.

Workaround: Before taking any action in Sybase Control Center, ensure that the primary server shutdown is complete and another server has taken over as the new primary.

CR-704913
When an iOS device goes offline, it continues to show as being online for about 8 minutes in Sybase Control Center.

Workaround: None.

CR-703367
Domain log messages in Data Sync and Operation Replay subsystems are not logged to the 'default' domain.

Workaround:

  • Create a domain log profile for the 'default' server connection (JDBC type) to enable logging of Data Sync and Operation Replay messages.
  • If you have a similar configuration, make changes as appropriate. Contact Technical Support for guidance.
CR-703321
Exporting a domain log after upgrading generates a Domain log export failed error message.

Workaround: Clear the cache for the browser you are using to access Sybase Control Center.

CR-696373
When retrieving a domain log for large data, you receive an unknown error in Sybase Control Center.

Workaround: Check whether the Unwired Server or Sybase Control Center agent.log reports an out of memory error. If so, increase the JVM heap size appropriately for Unwired Server from the Sybase Control Center Configuration tab.

If this does not resolve the issue, try decreasing the time range set in the domain log in Sybase Control Center.

CR-695792
Suspending a large volume (100 or more) of DOE-C package subscriptions may cause Unwired Server to stop responding.

Workaround: Suspend subscriptions in batches of no more than 50.

CR-691963
MBO package deployment in Update mode after adding a new load argument without default value succeeds even though deployment should fail.

Workaround: None. To avoid deploying client-incompatible changes, Sybase recommends that you first use Verify mode deployment; if verify succeeds, proceed to Update mode deployment.

CR-690482
Using Firefox, the Sybase Control Center main page shows Invalid Login and the agent.log shows Received fatal alert: bad_certificate error.
Workaround: The Firefox browser appears to be using an incorrect server certificate. Clean up any such previously existing certificates:
  1. Select Tools > Options > Advanced > View Certificates.
  2. Click the Servers tab, then identify existing certificates issued to the same host to which you are connecting.
  3. Click Delete to remove all such certificates. Alternatively, use Internet Explorer.
CR-683775
In some instances, when using the Windows Services tool or the Stop Sybase Control Center Service shortcut to stop the Sybase Control Center3.2 service, Sybase Control Center displays Stopping in the Windows Control Panel yet fails to stop.

Workaround: To stop the Sybase Control Center service:
  1. Launch Windows Task Manager.
  2. Locate the sccservice.exe process, right-click and select End Process Tree. This option also kills the Sybase Control Center database repository server process dbsrv11.exe.
n/a
Domains and Packages tab

Sybase Control Center for Online Data Proxy does not have a way to add a new domain to an application from the Application Properties dialog. Domains can only be associated in the Application Creation wizard.

RTC-396
Modification of JVM properties in SCC does not take effect if server is restarted using Windows Services

Workaround: Restart server from SCC, use restart-unwired-server.bat, or click the stop/start Unwired Server services icons.