Backup Server cannot dump to multi-disk volumes.
During the backup and restore process, change tape volumes. If the Backup Server detects a problem with the currently mounted volume, it requests a volume change by sending messages to either the client or its operator console. After mounting another volume, the operator notifies the Backup Server by executing sp_volchanged on Adaptive Server.
On UNIX systems, the Backup Server requests a volume change when the tape capacity has been reached. The operator mounts another tape and then executes sp_volchanged (see Table 27-2).
Sequence  | 
Operator using isql  | 
Adaptive Server  | 
Backup Server  | 
|---|---|---|---|
1  | 
Issues the dump database command  | 
||
2  | 
Sends dump request to Backup Server  | 
||
3  | 
Receives dump request message from Adaptive Server Sends message for tape mounting to operator Waits for operator’s reply  | 
||
4  | 
Receives volume change request from Backup Server Mounts tapes Executes sp_volchanged  | 
||
5  | 
Checks tapes If tapes are okay, begins dump When tape is full, sends volume change request to operator  | 
||
6  | 
Receives volume change request from Backup Server Mounts tapes Executes sp_volchanged  | 
||
7  | 
Continues dump When dump is complete, sends messages to operator and Adaptive Server  | 
||
8  | 
Receives message that dump is complete Removes and labels tapes  | 
Receives message that dump is complete Releases locks Completes the dump database command  |