RPCRebind

Description

Specifies whether you want PowerBuilder to rebind Remote Procedure Call (RPC) parameters.

NoteWhen to specify RPCRebind If your back-end DBMS supports it, you must specify the RPCRebind parameter before connecting to the database.

Applies to

Syntax

RPCRebind=value

Parameter

Description

value

Specifies whether you want PowerBuilder to rebind RPC parameters. Values are:

Default

RPCRebind=0

Usage

For those DBMSs that support RPC calls, PowerBuilder binds the parameters for the call based on the size of the variables bound to the parameters.

Some drivers require rebinding of the parameters so the parameter size (as returned from the back-end database) is used instead of the variable size. Failure to do this might result in an error or truncation for string parameters. However, some drivers always expect the binding to reflect the variable size. The RPCRebind parameter allows you to specify whether you want to rebind the parameters when RPCs are executed.