Read about updates, corrections, and clarifications to the documentation released with Sybase Event Stream Processor.
CR# | Description |
---|---|
N/A | The section on the JMS adapter shows you how to configure a queuing system for the JMS adapter. It should also mention that, to run the adapter, you must obtain and place vendor specific JMS jar files in the $ESP_HOME/java folder and restart the Server. |
716766 | The documentation incorrectly states the support provided for .NET as ".NET (C#,
Visual Basic, and so on)." It should say: .NET (C#) This correction applies to Custom Adapters in the Adapters Guide and the Studio Users Guide, and to What You Can Do with Sybase Event Stream Processor in the Getting Started Guide. |
717192 |
The description for the DB Service Name property in the ASE Output adapter section states that only Open Clientâ„¢ connections are supported. It should also state that an Open Client entry must be used in the service.xml file to be able to use the ASE Output adapter. See the sample service.xml file in ESP_HOME/bin for more information on this property. |
717862 | The RTView adapter documentation incorrectly specifies version 1.6 of Java; it should be version 1.7. |
CR# | Description |
---|---|
680686 | The guide should state: When you create a duplicate named window or stream in the Visual Editor, then save your file and switch to the Text Editor, a third duplicate of the original stream or window is created. You can see this third duplicate only when you switch back to the Visual Editor. Remove
this third duplicate:
|
682387 |
To redeploy a project after making changes to a
running project:
|
CR# | Description |
---|---|
643882 |
Delta streams are allowed key transformation only when performing aggregation, join, or flex operations. Because a delta stream does not maintain state, you cannot define a delta stream on a window where the keys differ. |
CR# | Description |
---|---|
682458 |
There are undocumented restrictions on user name and password credentials for the interactive mode of the esp_cluster_admin tool. Credentials may contain alpha numeric characters but must always start with an alphabetic character. For example, password 12345678 is invalid, whereas P12345678 is valid. |
682913 |
References to the "port number used by your Event Stream Processor installation" are referring to the port number of your cluster cache. |
717192 |
The External Database Access section should include information about using Open Client connections to connect to Adaptive Server Enterprise with the ASE Output adapter. You can only use Open Client connections with this adapter. The DriverLibrary parameter for Open Client
connections to Adaptive Server Enterprise should be
esp_db_ocs_lib. The connection block below is from the sample
service.xml file in the
ESP_HOME/bin directory that is provided
with Event Stream
Processor.
<!-- ONLY MEANT TO BE USED WITH ASE OUTPUT ADAPTER --> <Service Name="SampleOCSService" Type="DB"> <Parameter Name="DriverLibrary">esp_db_ocs_lib</Parameter> <Parameter Name="Host">localhost</Parameter> <Parameter Name="Port">5000</Parameter> <Parameter Name="User">sa</Parameter> <Parameter Name="Password"></Parameter> <Parameter Name="TDSPacketSize">2048</Parameter> <Parameter Name="AppName">ASEOutputAdapter</Parameter> </Service> |
CR# | Description |
---|---|
682458 |
There are undocumented restrictions on user name and password credentials for the interactive mode of the esp_cluster_admin tool. Credentials may contain alpha numeric characters but must always start with an alphabetic character. The document also provides an invalid sample password of 1234. |