Properties that configure default settings for all session connections.
Property Name | Type | Description |
---|---|---|
ConnectionType | string | (Required) Specifies whether the adapter acts as a server or a client. Each
adapter instance operates in either acceptor mode or initiator mode,
but cannot simultaneously operate in both modes. Valid values
are:
|
SocketAcceptPort | nonNegativeInteger | (Required) Specifies the port on which the adapter listens for connections from FIX session initiators. No default value. Operates only in initiator mode. |
FileLogPath | string | (Required) Specifies the directory path for message logs. Both absolute and
relative paths are accepted. No default value. Use a forward slash for both UNIX and Windows paths. |
FileStorePath | string | (Required) Specifies the directory path for message stores. Both absolute and
relative paths are accepted. No default value. Use a forward slash for both UNIX and Windows paths. |
StartTime | string | (Required) Specifies the time the FIX session is activated. No default value. |
EndTime | string | (Required) Specifies the time the FIX session is deactivated. No default value. |
DataDictionary | string | (Required) Specifies the absolute or relative paths to the FIX dictionary
file path. No default value. Use a forward slash for both UNIX and Windows paths. |
BeginString | string | (Required) Specifies the value of the BeginString field (tag 8) in outbound FIX messages. No default value. |
SenderCompID | string | (Required) Specifies the value of the SenderCompID field (tag 49) in outbound FIX messages. An adapter instance uses the same SenderCompID value for all session connections. |
HeartBtInt | nonNegativeInteger | (Optional)
Specifies the heartbeat interval, in seconds. Default value is 10. Operates only in initiator mode. |
ReconnectInterval | positiveInteger | (Optional)
Specifies the interval, in seconds, between reconnection
attempts. The adapter keeps trying to reconnect if it fails to connect to the acceptor engine at start-up or if the connection is lost afterward. Default value is 30. Operates only in initiator mode. |
LogonTimeout | nonNegativeInteger | (Optional)
Specifies the number of seconds to wait for a logon response before
disconnecting from the acceptor engine. Default value is 10. Operates only in initiator mode. |
LogoutTimeout | nonNegativeInteger | (Optional)
Specifies the number of seconds to wait for a logout response before
disconnecting from the acceptor engine. Default value is 2. Operates only in initiator mode. |