The FIX Input adapter reads FIX messages from any number of file, socket, and session connectors.
Property Label | Property ID | Type | Description |
---|---|---|---|
Adapter Directory Path | baseDir | directory | (Required) Specifies the path to the adapter base directory. No default value. Note: This property is ignored if the Connector Remote
Directory Path property is supplied.
|
Configuration File Path | configFilePath | configFilename | (Required) Specifies the absolute path to the adapter configuration file. No default value. Note: This
property is ignored if the Remote Configuration File
Path property is supplied.
|
PropertySet |
propertyset | string | (Advanced) Specifies the name of the property set (a group of properties and values) you want to use from the project configuration file. If you specify the same properties in the project configuration file and the ATTACH ADAPTER statement, the values in the property set override the values defined in the ATTACH ADAPTER statement. No default value. |
Adapter Remote Directory | remoteBaseDir | string | (Advanced) Specifies the path to the adapter remote base directory (for remote execution only). No default value. Note: If this property is supplied, the Connector Directory Path property is ignored.
|
Adapter Configuration File Path | remoteConfigFilePath | string | (Advanced) Specifies the absolute path to the adapter configuration file (for
remote execution only). No default value. Note: If this property is supplied, the configuration file path property is ignored.
|