File FIX Input Adapter

Adapter type: fixfile_in. The File FIX Input adapter reads FIX messages from a file and writes them as stream records.

Each stream hosts FIX messages of a certain type. The adapter ignores messages of any other FIX type. It writes all FIX fields, except the following, in the same order in stream columns:
  • BeginString
  • BodyLength
  • MsgType
  • CheckSum

Ensure the names of the stream columns correspond to the FIX protocol specification.

If you use the CCL ATTACH ADAPTER statement to attach an adapter, you must supply the adapter type. The type for this adapter is fixfile_in.

Property Label Property ID Type Description
FIX Version fixVersion choice (Required) Version of the FIX protocol. Default value is 4.2.
FIX Message Type fixMessageType string (Required) Type of messages hosted by the stream. No default value.
File fileName filename (Required) Path to the input file containing FIX messages. No default value.
Date Format dateFormat string (Advanced) Date format. Default value is YYYY-MM-DDTHH:MM:SS.SSS.
Timestamp Format timestampFormat string (Advanced) Timestamp format. Default value is YYYY-MM-DDTHH:MM:SS.SSS.

PropertySet

propertyset string

(Advanced) Specifies the name of the property set (a group of properties and values) you want to use from the project configuration file. If you specify the same properties in the project configuration file and the ATTACH ADAPTER statement, the values in the property set override the values defined in the ATTACH ADAPTER statement. No default value.

Known limitations:
  • This adapter is not a full FIX Engine.
  • Supports only FIX versions 4.2, 4.3, 4.4, and 5.0.
  • Does not support repeating groups and components.
  • Supports only INSERT opcode.
Related concepts
FIX Adapter