Known Issues for Unwired Platform Runtime 2.2 SP03

Learn about known issues and apply workarounds for Unwired Platform runtime components.

Key to issue types:
Issue #Description
RTC-113
Login fails when the value of the "tm_max_no" parameter in the SAP® EIS is less than the number of users concurrently logged in.

The value of the tm_max_no parameter in the SAP EIS limits the maximum number of active logins. If the number of concurrent users logged in is larger than this value, Unwired Server shows a R3_LOGIN_FAILED error.

Workaround: Increase the value of the tm_max_no parameter in the SAP EIS to a suitable value.

CR-714679
Sybase Control Center stops responding and shows Connecting with the SCC Managed Object Server message after login.

Workaround: Instead of using the standard URL (https:// < hostname > :8283/scc), if you are accessing Sybase Control Center from the same host use https://localhost:8283/scc or https:// < host name.domain > :8283/scc. Another option is to try accessing from a remote machine.