This section describes how to move data from a database in big-endian format to a database in little-endian format. This procedure moves table definitions but does not include migration of database objects, such as stored procedures or events, which you must re-create.
For example, Sybase IQ databases built on Sun64 SPARC systems store binary data in big-endian (most significant byte first) format. Because Sun Solaris x64 is a little-endian system, you cannot upgrade Sybase IQ databases built on Sun64 SPARC with ALTER DATABASE UPGRADE to run on Sun Solaris x64 systems.
To move data for each database across hardware platforms of different endian structures, you must:
Copy the database schema from the source platform (tables, indexes, and so on).
Create a new database on the target platform.
Perform a binary data dump from the source database.
Load data into the new target database.
Moving data from big-endian to little-endian systems or the reverse
Before you begin, make sure that you have a process for capturing your database and table schema.
The following example loads a table named lineitem and identifies one extract file on UFS (file system) called lineitem_binary.inp.
Check operating system documentation for the maximum file size for your system. For example, an extract file on Sun Solaris x64 has a maximum size of 512GB.
Activate the extract utility:
SET TEMPORARY OPTION Temp_Extract_Name1 = 'lineitem_binary.inp'
SET TEMPORARY OPTION Temp_Extract_Name2 = ''
Set up a binary extract of the lineitem table:
SET TEMPORARY OPTION Temp_Extract_Binary = 'on'
SET TEMPORARY OPTION Temp_Extract_Swap = 'off'
Place output in the file lineitem_binary.inp:
SELECT * FROM lineitem
Turn off the extract utility:
SET TEMPORARY OPTION Temp_Extract_Name1 = ''
Create a duplicate of your database on the target system.
Assuming table lineitem as defined below, load the lineitem table as follows:
LOAD TABLE lineitem ( l_orderkey BINARY WITH NULL BYTE, l_partkey BINARY WITH NULL BYTE, l_suppkey BINARY WITH NULL BYTE, l_linenumber BINARY WITH NULL BYTE, l_quantity BINARY WITH NULL BYTE, l_extendedprice BINARY WITH NULL BYTE, l_discount BINARY WITH NULL BYTE, l_tax BINARY WITH NULL BYTE, l_returnflag BINARY WITH NULL BYTE, l_linestatus BINARY WITH NULL BYTE, l_shipdate BINARY WITH NULL BYTE, l_commitdate BINARY WITH NULL BYTE, l_receiptdate BINARY WITH NULL BYTE, l_shipinstruct BINARY WITH NULL BYTE, l_shipmode BINARY WITH NULL BYTE, l_comment BINARY WITH NULL BYTE ) FROM 'C:\\mydata\\lineitem_binary.inp' FORMAT BINARY STRIP OFF QUOTES OFF ESCAPES OFF PREVIEW ON BYTE ORDER HIGH; COMMIT
Note particularly two clauses:
BINARY WITH NULL BYTE is required when loading a binary file.
BYTE ORDER HIGH specifies the byte order from the system where the data originated. The source database in this example is a big-endian platform; therefore, this data requires byte order HIGH. (Little-endian databases require byte order LOW.)
When loading a multiplex database, use absolute (fully qualified) paths in all file names. Do not use relative path names.