Preparing the SAP Gateway

Configure the SAP Gateway to push OData application data to Unwired Server, including configuring the RFC destination for HTTPS on the Gateway.

  1. Log on to a Gateway system and go to transaction sm59.
  2. Create a RFC connection of type G.
  3. Enter the domain name of Unwired Server (CN of the Unwired Server certificate) in the Target Host field .
  4. Enter /GWC/SUPNotification in the Path Prefix field.
  5. Enter 8004 in the Service No. field.
  6. Select the Logon & Security tab.
  7. Under Security Options, click the SSL Active option.
  8. Select Default SSL Client (Standard) from the SSL Certificate drop-down list.
  9. Click Save, then Connection Test.
    The test should be successful, a HTTP OK success message displays.
    Note: Change the push endpoint in the proxy property of the application templates to https://<domain name of the SUP server>:<SSL Port>/GWC/SUPNotification/. In this example, 8004 is the SSL port to which the Gateway pushes data changes:
    https://inln50089324a.dhcp.blrl.sap.corp:8004/GWC/SUPNotification/