Second Sybase Control Center Fails to Start

Problem: Cannot start a second co-existing Sybase Control Center in a deployment environment.

Explanation: When multiple versions of Sybase Control Center co-exist on a single machine, if the older version is already using the default port number, the new version of Sybase Control Center uses another port number, such as 8285. If the configuration files have not been updated, this may cause port conflicts.

Solution: Check the port numbers, and check the configuration files to make sure the configuration is correct. See the topic Port Number Reference. If the configuration is correct, you may need to start the second version of Sybase Control Center manually.

Related concepts
Sybase Unified Agent Windows Service Fails to Start
Related reference
Launching SCC Results in Rounded Rectangle Box or Empty Console Screen
Sybase Unified Agent Windows Service Deleted
Sybase Control Center Fails to Start
Login Invalid in Sybase Control Center
Cannot Access Unwired Platform Administration Nodes
Previous Administrator Credentials Used
Browser Refresh (F5) Causes Logout
Security Error Triggered When Connecting to SCC from Remote Browser
Administrator Login Passes When Provider Is Not Available
Host Name of Registered Resource Changed But Is Not Updated