SMTP gateway properties

SMTP gateway properties allow you to change the behavior of an SMTP gateway. The server property is required; all other SMTP gateway properties are optional. For more information about setting these properties, see MobiLink server settings for server-initiated synchronization.

Property Value Description
confirm_action { yes | no } Specifies whether confirmation is sent on delivery through this gateway. The default value is no.
confirm_delivery { yes | no } Specifies whether this gateway confirms delivery. The default value is no.
confirm_timeout number{ s | m | h }

Specifies the amount of time to wait before confirmations timeout. The following is a list of acceptable time units:

  • s: Denotes seconds.
  • m: Denotes minutes.
  • h: Denotes hours.

The default value is 1m. Time units can be combined in the HHh MMm SSs format. If a time unit is not specified, time is measured in seconds.

description description_text Describes the gateway.
enable { yes | no } Specifies whether the SYNC gateway should be used.
Listeners_are_900 { yes | no } Specifies whether all MobiLink Listeners are SQL Anywhere 9.0.0 clients. The default value is no. For SQL Anywhere 9.0.1 clients or later, leave this value at no.
password password Specifies the password for the SMTP service. This is required by some services.
sender SMTP_address Specifies the sender address of SMTP push notifications. The default value is anonymous.
server IP_address_or_hostname Specifies the IP address or host name of the SMTP server used to send messages to a MobiLink Listener. The default value is mail.
user username Specifies the user name of the SMTP service. This is required by some services.