Known issues  General issues

Release Bulletin Enterprise Connect™ Data Access 12.6 for Linux and UNIX

DirectConnect issues

The following table lists outstanding issues that apply to DirectConnect products. Each issue identifies specific hardware or operating system information, a workaround (if available), and the QTS assigned to it.

Known issues for specific DirectConnect products without QTS identifiers are described in sections following this table.

Table 6: Known issues for DirectConnect products

Product

Platform

Description

Workaround

QTS #

All DirectConnects except DirectConnect for Oracle

All

Express transfer does not support the transfer of char datatypes to and from decimal datatypes.

Convert query datatypes from char to decimal datatypes in the transfer query statement by using the SQL CAST function.

None

Express transfer does not support the transfer of text datatypes to and from char datatypes.

Convert query datatypes from text to char datatypes in the transfer query statement by using the SQL CAST function.

DirectConnect for DB2 UDB only

All

CLOB data is limited to 32K. BLOB datatype is not supported.

Use DirectConnect for z/OS.

None

All

Using the AlternateID property to connect to the mainframe causes errors.

None.

385229

All

DB2 varchar datatype larger than 255 characters is incorrectly reported as a varchar datatype by the sp_columns property.

None. (A fix is expected in 12.6 ESD #1.)

383494 385500

All

Specifying host name as the IP Address will cause a failure on some Sun Solaris systems.

The IP Number must be specified as the IP Address.

None





Copyright © 2005. Sybase Inc. All rights reserved. General issues

View this release bulletin as PDF